SCHNEIDER Altivar 61 Variable speed drive ATV61HD11N4 11KW

Main
Range of product Altivar 61
Product or component type Variable speed drive
Product specific application Pumping and ventilation machine
Component name ATV61
motor power kW 11 kW, 3 phases at 380…480 V
motor power hp 15 hp, 3 phases at 380…480 V
power supply voltage 380…480 V – 15…10 %
supply number of phases 3 phases
line current 30 A for 480 V 3 phases 11 kW / 15 hp
36.6 A for 380 V 3 phases 11 kW / 15 hp
EMC filter Level 3 EMC filter
Assembly style With heat sink
apparent power 24.1 kVA at 380 V 3 phases 11 kW / 15 hp
maximum prospective line Isc 22 kA for 3 phases
maximum transient current 33.2 A for 60 s, 3 phases
Nominal switching frequency 12 kHz
switching frequency 1…16 kHz adjustable
12…16 kHz with derating factor
asynchronous motor control Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio – Energy Saving, quadratic U/f
Synchronous motor control profile Vector control without sensor, standard
communication port protocol Modbus
CANopen

 

Complementary
Product destination Synchronous motors
Asynchronous motors
power supply voltage limits 323…528 V
power supply frequency 50…60 Hz – 5…5 %
power supply frequency limits 47.5…63 Hz
continuous output current 21 A at 12 kHz, 460 V – 3 phases
27.7 A at 12 kHz, 380 V – 3 phases
Output frequency 0.1…599 Hz
speed range 1…100 in open-loop mode, without speed feedback
speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
torque accuracy +/- 15 % in open-loop mode, without speed feedback
transient overtorque 130 % of nominal motor torque +/- 10 % for 60 s
braking torque <= 125 % with braking resistor
30 % without braking resistor
Regulation loop Frequency PI regulator
Motor slip compensation Automatic whatever the load
Can be suppressed
Not available in voltage/frequency ratio (2 or 5 points)
Adjustable
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage
electrical isolation Between power and control terminals
,

ATV61HC16N4 SCHNEIDER SPEEDDRIVE,250HP,460V,ATV61

range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
160 kW, 3 phase 380…480 V
Maximum Horse Power Rating
250 hp, 3 phase 380…480 V
power supply voltage
380…480 V – 15…10 %
supply number of phases
3 phase
line current
275 A 480 V 3 phase 160 kW / 250 hp
289 A 380 V 3 phase 160 kW / 250 hp
EMC filter
Level 3 EMC filter
assembly style
With heat sink
apparent power
190.2 kVA 380 V 3 phase 160 kW / 250 hp
maximum prospective line Isc
50 kA 3 phase
maximum transient current
376.8 A 60 s, 3 phase
nominal switching frequency
2.5 kHz
switching frequency
2…8 kHz adjustable
2.5…8 kHz with derating factor
asynchronous motor control
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 points
Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
CANopen
Modbus
type of polarization
No impedance Modbus
,

Schneider Variable speed drives ATV61HC16N4D 160kW, 3 phase 380…480 V

range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
160 kW, 3 phase 380…480 V
Maximum Horse Power Rating
250 hp, 3 phase 380…480 V
power supply voltage
380…480 V – 15…10 %
supply number of phases
3 phase
line current
275 A 480 V 3 phase 160 kW / 250 hp
289 A 380 V 3 phase 160 kW / 250 hp
EMC filter
Level 3 EMC filter
assembly style
With heat sink
apparent power
190.2 kVA 380 V 3 phase 160 kW / 250 hp
maximum prospective line Isc
50 kA 3 phase
maximum transient current
376.8 A 60 s, 3 phase
nominal switching frequency
2.5 kHz
switching frequency
2…8 kHz adjustable
2.5…8 kHz with derating factor
asynchronous motor control
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 points
Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
CANopen
Modbus
,

Schneider ATV61HD75N4S337 variable speed drive ATV61 – 75kW

Schneider ATV61HD75N4S337 variable speed drive ATV61 – 75kW

  • variable speed drive ATV61
  • 75kW 100HP – 380…480V
  • IP20 – reinforced
Main
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
75 kW 3 phasesat 380…480 V
motor power hp
100 hp 3 phasesat 380…480 V
[Us] rated supply voltage
380…480 V (- 15…10 %)
Phase
3 phases
line current
137 Afor 480 V 3 phases 75 kW / 100 hp 167 Afor 380 V 3 phases 75 kW / 100 hp
EMC filter
Level 3 EMC filter
variant
Reinforced version
assembly style
With heat sink
apparent power
109.9 kVAfor 380 V 3 phases 75 kW / 100 hp
prospective line Isc
22 kA 3 phases
maximum transient current
192 A for 60 s 3 phases
nominal switching frequency
12 kHz
switching frequency
1…16 kHz adjustable 12…16 kHz with derating factor
asynchronous motor control profile
Voltage/frequency ratio, 2 points Flux vector control without sensor, standard Voltage/frequency ratio – Energy Saving, quadratic U/f Voltage/frequency ratio, 5 points
synchronous motor control profile
Vector control without sensor, standard
,

ATV61HC40N4D Schneider ATV61 drives 400KW 3P,380VAC

range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
355 kW, 3 phase 380…480 V
400 kW, 3 phase 380…480 V
Maximum Horse Power Rating
600 hp, 3 phase 380…480 V
power supply voltage
380…480 V – 15…10 %
supply number of phases
3 phase
line current
597 A 480 V 3 phase 355 kW
637 A 380 V 3 phase 355 kW
644 A 480 V 3 phase 400 kW / 600 hp
709 A 380 V 3 phase 400 kW / 600 hp
EMC filter
Level 3 EMC filter
variant
Without DC choke
assembly style
With heat sink
apparent power
419.3 kVA 380 V 3 phase 355 kW
466.6 kVA 380 V 3 phase 400 kW / 600 hp
maximum prospective line Isc
50 kA 3 phase
maximum transient current
910.8 A 60 s, 3 phase
nominal switching frequency
2.5 kHz
switching frequency
2…8 kHz adjustable
2.5…8 kHz with derating factor
asynchronous motor control
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 2 points
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
Modbus
CANopen
type of polarization
No impedance Modbus
,

ATV61HC31N4D Schneider Altivar 61 SPEED DRIVE 500HP,460V

ATV61HC31N4D Schneider Altivar 61 SPEED DRIVE 500HP,460V

Characteristics

Main
range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
280 kW 3 phasesat 380…480 V 315 kW 3 phasesat 380…480 V
motor power hp
450 hp 3 phasesat 380…480 V 500 hp 3 phasesat 380…480 V
[Us] rated supply voltage
380…480 V (- 15…10 %)
Phase
3 phases
line current
494 Afor 380 V 3 phases 280 kW / 450 hp 494 Afor 480 V 3 phases 280 kW / 450 hp 544 Afor 480 V 3 phases 315 kW / 500 hp 555 Afor 380 V 3 phases 315 kW / 500 hp
EMC filter
Level 3 EMC filter
variant
Without DC choke
assembly style
With heat sink
apparent power
325.1 kVAfor 380 V 3 phases 280 kW / 450 hp 365.3 kVAfor 380 V 3 phases 315 kW / 500 hp
prospective line Isc
50 kA 3 phases
maximum transient current
739.2 Afor 60 s 3 phases
nominal switching frequency
2.5 kHz
switching frequency
2…8 kHz adjustable 2.5…8 kHz with derating factor
asynchronous motor control profile
Voltage/frequency ratio, 5 points Voltage/frequency ratio – Energy Saving, quadratic U/f Voltage/frequency ratio, 2 points Flux vector control without sensor, standard
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
Modbus CANopen
type of polarization
No impedance Modbus
,

ATV61HC63N4 630kW 900HP – 380…480V – IP20

ATV61HC63N4D Altivar 61  Variable speed drive Variable speed drive ATV61 – 630kW 900HP – 380…480V – IP20

,

ATV61HD90M3X Schneider ATV61 DRIVES 90KW 3AC 200…240V

Mainrange of product

Altivar 61

product or component type

Variable speed drive

product specific application

Pumping and ventilation machine

component name

ATV61

motor power kW

90 kW 3 phasesat 200…240 V

motor power hp

125 hp 3 phasesat 200…240 V

[Us] rated supply voltage

200…240 V (- 15…10 %)

Phase

3 phases

line current

288 Afor 240 V 3 phases 90 kW / 125 hp 336 Afor 200 V 3 phases 90 kW / 125 hp

EMC filter

Without EMC filter

assembly style

With heat sink

apparent power

119.7 kVAfor 240 V 3 phases 90 kW / 125 hp

prospective line Isc

35 kA 3 phases

maximum transient current

431 Afor 60 s 3 phases

nominal switching frequency

2.5 kHz

switching frequency

2.5…8 kHz adjustable 2.5…8 kHz with derating factor

asynchronous motor control profile

Voltage/frequency ratio, 2 points Voltage/frequency ratio – Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, 5 points

synchronous motor control profile

Vector control without sensor, standard

communication port protocol

CANopen Modbus

ATV61H075M3 Schneider Speed Drive Or Component Type ATV61

range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
0.37 kW single phase at 200…240 V 0.75 kW 3 phases at 200…240 V
motor power hp
1 hp 3 phases at 200…240 V 0.5 hp single phase at 200…240 V
[Us] rated supply voltage
200…240 V (- 15…10 %)
network number of phases
Single phase 3 phases
line current
5.3 A for 240 V 3 phases 0.75 kW / 1 hp 5.8 A for 240 V single phase 0.37 kW / 0.5 hp 6.1 A for 200 V 3 phases 0.75 kW / 1 hp 6.9 A for 200 V single phase 0.37 kW / 0.5 hp
EMC filter
Class C2 EMC filter integrated
assembly style
With heat sink
apparent power
1.4 kVA for 240 V single phase 0.37 kW / 0.5 hp 2.2 kVA for 240 V 3 phases 0.75 kW / 1 hp
prospective line Isc
5 kA 3 phases 5 kA single phase
maximum transient current
3.6 A for 60 s single phase 5.7 A for 60 s 3 phases
nominal switching frequency
12 kHz
switching frequency
1…16 kHz adjustable 12…16 kHz with derating factor
asynchronous motor control profile
Voltage/frequency ratio, 5 points Voltage/frequency ratio, 2 points Flux vector control without sensor, standard Voltage/frequency ratio – Energy Saving, quadratic U/f
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
CANopen Modbus
type of polarization
No impedance for Modbus
option card
APOGEE FLN communication card BACnet communication card CC-Link communication card Controller inside programmable card DeviceNet communication card Ethernet/IP communication card Fipio communication card I/O extension card Interbus-S communication card LonWorks communication card METASYS N2 communication card Modbus Plus communication card Modbus TCP communication card Modbus/Uni-Telway communication card Multi-pump card Profibus DP communication card Profibus DP V1 communication card
 
product destination
Asynchronous motors Synchronous motors
supply voltage limits
170…264 V
supply frequency
50…60 Hz (- 5…5 %)
network frequency
47.5…63 Hz
continuous output current
3 A at 12 kHz, 230 V single phase 4.8 A at 12 kHz, 230 V 3 phases
output frequency
0.1…599 Hz
speed range
1…100 in open-loop mode, without speed feedback
speed accuracy
+/- 10 % of nominal slip for 0.2 Tn to Tn torque variation without speed feedback
torque accuracy
+/- 15 % in open-loop mode, without speed feedback
transient overtorque
130 % of nominal motor torque, +/- 10 % for 60 s
braking torque
30 % without braking resistor <= 125 % with braking resistor
regulation loop
Frequency PI regulator
motor slip compensation
Automatic whatever the load Not available in voltage/frequency ratio (2 or 5 points) Adjustable Can be suppressed
local signalling
1 LED red presence of drive voltage
output voltage
<= power supply voltage
isolation
Between power and control terminals
type of cable
With an IP21 or an IP31 kit : 3-strand IEC cable at 40 °C, copper 70 °C PVC Without mounting kit : 1-strand IEC cable at 45 °C, copper 70 °C PVC Without mounting kit : 1-strand IEC cable at 45 °C, copper 90 °C XLPE/EPR With UL Type 1 kit : 3-strand UL 508 cable at 40 °C, copper 75 °C PVC
electrical connection
AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR terminal 2.5 mm² / AWG 14 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB terminal 6 mm² / AWG 8
tightening torque
AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR 0.6 N.m L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB 1.4 N.m / 12.3 lb.in
supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <= 10 mA for overload and short-circuit protection Internal supply 24 V DC (21…27 V), <= 200 mA for overload and short-circuit protection External supply 24 V DC (19…30 V)
analogue input number
2
analogue input type
AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input voltage 24 V max, resolution 11 bits + sign AI2 software-configurable current 0…20 mA, impedance 242 Ohm, resolution 11 bits AI2 software-configurable voltage 0…10 V DC, input voltage 24 V max, impedance 30000 Ohm, resolution 11 bits
sampling duration
Discrete input LI6 (if configured as logic input) 2 ms, +/- 0.5 ms Analog input AI1-/Al1+ 2 ms, +/- 0.5 ms Analog input Al2 2 ms, +/- 0.5 ms Analog output AO1 2 ms, +/- 0.5 ms Discrete input LI1…LI5 2 ms, +/- 0.5 ms
accuracy
AI1-/Al1+ +/- 0.6 % for a temperature variation 60 °C AI2 +/- 0.6 % for a temperature variation 60 °C AO1 +/- 1 % for a temperature variation 60 °C
linearity error
AI1-/Al1+ +/- 0.15 % of maximum value AI2 +/- 0.15 % of maximum value AO1 +/- 0.2 %
analogue output number
1
analogue output type
AO1 software-configurable current, analogue output range 0…20 mA, impedance 500 Ohm, resolution 10 bits AO1 software-configurable logic output 10 V, <= 20 mA AO1 software-configurable voltage, analogue output range 0…10 V DC, impedance 470 Ohm, resolution 10 bits
discrete output number
2
discrete output type
(R1A, R1B, R1C) configurable relay logic NO/NC, electrical durability 100000 cycles (R2A, R2B) configurable relay logic NO, electrical durability 100000 cycles
response time
<= 100 ms in STO (Safe Torque Off) R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms R2A, R2B <= 7 ms, tolerance +/- 0.5 ms
minimum switching current
Configurable relay logic 3 mA at 24 V DC
maximum switching current
R1, R2 on resistive load, 5 A at 30 V DC, cos phi = 1, 0 ms R1, R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4, 7 ms R1, R2 on resistive load, 5 A at 250 V AC, cos phi = 1, 0 ms R1, R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, 7 ms
discrete input number
7
discrete input type
(LI1…LI5) programmable, 24 V DC, voltage limits <= 30 V, with level 1 PLC, impedance 3500 Ohm (LI6) switch-configurable, 24 V DC, voltage limits <= 30 V, with level 1 PLC, impedance 3500 Ohm (LI6) switch-configurable PTC probe, 0…6, impedance 1500 Ohm (PWR) safety input, 24 V DC, voltage limits <= 30 V, impedance 1500 Ohm
discrete input logic
LI1…LI5 positive logic (source), < 5 V (state 0), > 11 V (state 1) LI1…LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 1) LI6 (if configured as logic input) negative logic (sink), > 16 V (state 0), < 10 V (state 1) LI6 (if configured as logic input) positive logic (source), < 5 V (state 0), > 11 V (state 1)
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s Automatic adaptation of ramp if braking capacity exceeded, by using resistor S, U or customized
braking to standstill
By DC injection
protection type
Drive against exceeding limit speed Drive against input phase loss Drive break on the control circuit Drive input phase breaks Drive line supply overvoltage Drive line supply undervoltage Drive overcurrent between output phases and earth Drive overheating protection Drive overvoltages on the DC bus Drive power removal Drive short-circuit between motor phases Drive thermal protection Motor motor phase break Motor power removal Motor thermal protection
insulation resistance
> 1 mOhm at 500 V DC for 1 minute to earth
frequency resolution
Analog input 0.024/50 Hz Display unit 0.1 Hz
connector type
1 RJ45 for Modbus on front face 1 RJ45 for Modbus on terminal Male SUB-D 9 on RJ45 for CANopen
physical interface
2-wire RS 485 for Modbus
transmission frame
RTU for Modbus
transmission rate
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal 9600 bps, 19200 bps for Modbus on front face
data format
8 bits, 1 stop, even parity for Modbus on front face 8 bits, odd even or no configurable parity for Modbus on terminal
number of addresses
1…247 for Modbus 1…127 for CANopen
method of access
Slave for CANopen
marking
CE
operating position
Vertical +/- 10 degree
product weight
3 kg
width
130 mm
height
230 mm
depth
175 mm
 
noise level
43 dB conforming to 86/188/EEC
dielectric strength
2830 V DC between earth and power terminals 4230 V DC between control and power terminals
electromagnetic compatibility
Conforming to IEC 61000-4-2 level 3 Conforming to IEC 61000-4-11 Conforming to IEC 61000-4-6 level 3 Conforming to IEC 61000-4-3 level 3 Conforming to IEC 61000-4-4 level 4
standards
EN 55011 class A group 1 IEC 60721-3-3 class 3S2 EN/IEC 61800-5-1 EN/IEC 61800-3 IEC 60721-3-3 class 3C1 EN 61800-3 environments 2 category C2 EN 61800-3 environments 1 category C2 UL Type 1
product certifications
C-Tick CSA UL GOST NOM 117 DNV
pollution degree
2 conforming to EN/IEC 61800-5-1
IP degree of protection
IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP54 on lower part conforming to EN/IEC 60529 IP54 on lower part conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f = 3…13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
shock resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3
ambient air temperature for operation
-10…50 °C without derating 50…60 °C with derating factor
ambient air temperature for storage
-25…70 °C
operating altitude
<= 1000 m without derating 1000…3000 m with current derating 1 % per 100 m
,

ATV61HC11Y Schneider variable speed drive ATV61 – 110kW 690V 125HP

ATV61HC11Y Schneider variable speed drive ATV61 – 110kW

  • Variable Speed Drives and Soft Starters
  • Low Voltage AC General Purpose Drives
  • Altivar 61
  • variable speed drive ATV61 – 110kW / 690V – 125HP / 575V – IP20
  • range of product
    Altivar 61
    product or component type
    Variable speed drive
    product specific application
    Pumping and ventilation machine
    component name
    ATV61
    motor power kW
    110 kW 3 phases at 690 V 90 kW 3 phases at 500 V
    motor power hp
    125 hp 3 phases at 575 V
    [Us] rated supply voltage
    500…690 V (- 15…10 %)
    network number of phases
    3 phases
    line current
    113 A for 600 V 3 phases 90 kW / 125 hp 117 A for 690 V 3 phases 90 kW / 125 hp 128 A for 500 V 3 phases 90 kW / 125 hp
    EMC filter
    Level 3 EMC filter
    assembly style
    With heat sink