ATV71HD90N4D Schneider ATV71 AC DRIVES 90kW-125HP – 480V EMC filter

ATV71HD90N4D Schneider ATV 71 AC DRIVES 90kw variable speed drive ATV71 – 90kW-125HP – 480V – EMC filter-graphic terminal

range of product
Altivar 71
product or component type
Variable speed drive
product specific application
Complex, high-power machines
component name
ATV71
motor power kW
90 kWat 380…480 V 3 phases
motor power hp
125 hpat 380…480 V 3 phases
motor cable length
<= 656.17 ft (200 m) Unshielded cable <= 328.08 ft (100 m) Shielded cable
[Us] rated supply voltage
380…480 V (- 15…10 %)
Phase
3 phases
line current
134 Afor 480 V 3 phases 90 kW / 125 hp 166 Afor 380 V 3 phases 90 kW / 125 hp
EMC filter
Integrated
assembly style
With heat sink
variant
Reinforced version Without DC choke
apparent power
109.3 kVAat 380 V 3 phases 90 kW / 125 hp
prospective line Isc
<= 35 kA, 3 phases
nominal output current
179 Aat 2.5 kHz 380 V 3 phases 90 kW / 125 hp 179 Aat 2.5 kHz 460 V 3 phases 90 kW / 125 hp
maximum transient current
269 Afor 60 s 3 phases 90 kW / 125 hp 295 Afor 2 s 3 phases 90 kW / 125 hp
output frequency
0.1…500 Hz
nominal switching frequency
2.5 kHz
switching frequency
2.5…8 kHz adjustable 2.5…8 kHz with derating factor
asynchronous motor control profile
Voltage/frequency ratio (2 or 5 points) ENA (Energy adaptation) system for unbalanced loads Sensorless flux vector control (SFVC) (voltage or current vector) Flux vector control (FVC) with sensor (current vector)
type of polarization
No impedance Modbus

ATV71HU15N4 Schneider Inverter Drive ATV71 Speed Drive 1.5kW

ATV71HU15N4 Schneider Inverter Drive ATV71 Speed Drive 1.5kW 2HP

Main
range of product
Altivar 71
product or component type
Variable speed drive
product specific application
Complex, high-power machines
component name
ATV71
motor power kW
1.5 kW at 380…480 V 3 phases
motor power hp
2 hp at 380…480 V 3 phases
motor cable length
<= 50 m Shielded cable <= 100 m Unshielded cable
[Us] rated supply voltage
380…480 V (- 15…10 %)
network number of phases
3 phases
line current
5.3 A for 480 V 3 phases 1.5 kW / 2 hp 5.8 A for 380 V 3 phases 1.5 kW / 2 hp
EMC filter
Integrated
assembly style
With heat sink
apparent power
3.8 kVA at 380 V 3 phases 1.5 kW / 2 hp
prospective line Isc
<= 5 kA, 3 phases
nominal output current
3.4 A at 4 kHz 460 V 3 phases 1.5 kW / 2 hp 4.1 A at 4 kHz 380 V 3 phases 1.5 kW / 2 hp
maximum transient current
6.2 A for 60 s 3 phases 1.5 kW / 2 hp 6.8 A for 2 s 3 phases 1.5 kW / 2 hp
output frequency
0.1…599 Hz
nominal switching frequency
4 kHz
switching frequency
1…16 kHz adjustable 4…16 kHz with derating factor
asynchronous motor control profile
ENA (Energy adaptation) system for unbalanced loads Sensorless flux vector control (SFVC) (voltage or current vector) Flux vector control (FVC) with sensor (current vector) Voltage/frequency ratio (2 or 5 points)
type of polarization
No impedance for Modbus
Complementary
product destination
Asynchronous motors Synchronous motors
supply voltage limits
323…528 V
supply frequency
50…60 Hz (- 5…5 %)
network frequency
47.5…63 Hz
speed range
1…100 for asynchronous motor in open-loop mode, without speed feedback 1…50 for synchronous motor in open-loop mode, without speed feedback 1…1000 for asynchronous motor in closed-loop mode with encoder feedback
speed accuracy
+/- 0.01 % of nominal speed for 0.2 Tn to Tn torque variation in closed-loop mode with encoder feedback +/- 10 % of nominal slip for 0.2 Tn to Tn torque variation without speed feedback
torque accuracy
+/- 15 % in open-loop mode, without speed feedback +/- 5 % in closed-loop mode with encoder feedback
transient overtorque
220 % of nominal motor torque +/- 10 % for 2 s 170 % of nominal motor torque +/- 10 % for 60 s every 10 minutes
braking torque
<= 150 % with braking or hoist resistor 30 % without braking resistor
synchronous motor control profile
Vector control without speed feedback
regulation loop
Adjustable PI regulator
motor slip compensation
Adjustable Suppressable Automatic whatever the load Not available in voltage/frequency ratio (2 or 5 points)
local signalling
1 LED red presence of drive voltage
output voltage
<= power supply voltage
insulation
Electrical between power and control
type of cable
With a NEMA Type1 kit : 3-strand UL 508 cable at 40 °C, copper 75 °C PVC With an IP21 or an IP31 kit : 3-strand IEC cable at 40 °C, copper 70 °C PVC Without mounting kit : 1-strand IEC cable at 45 °C, copper 70 °C PVC Without mounting kit : 1-strand IEC cable at 45 °C, copper 90 °C XLPE/EPR
electrical connection
AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR terminal 2.5 mm² / AWG 14 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB terminal 4 mm² / AWG 10
tightening torque
AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR 0.6 N.m L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB 1.4 N.m / 12.3 lb.in
supply
Internal supply for reference potentiometer (1 to 10 kOhm), 10.5 V DC +/- 5 %, <= 10 mA for overload and short-circuit protection Internal supply, 24 V DC, voltage limits 21…27 V, <= 200 mA for overload and short-circuit protection
analogue input number
2
analogue input type
AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input voltage 24 V max, resolution 11 bits + sign AI2 software-configurable current 0…20 mA, impedance 242 Ohm, resolution 11 bits AI2 software-configurable voltage 0…10 V DC, input voltage 24 V max, impedance 30000 Ohm, resolution 11 bits
sampling duration
AI1-/Al1+ 2 ms, +/- 0.5 ms for analog input(s) Al2 2 ms, +/- 0.5 ms for analog input(s) LI1…LI5 2 ms, +/- 0.5 ms for discrete input(s) LI6 (if configured as logic input) 2 ms, +/- 0.5 ms for discrete input(s)
response time
<= 100 ms in STO (Safe Torque Off) AO1 2 ms, tolerance +/- 0.5 ms for analog output(s) R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s) R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s)
accuracy
AI1-/Al1+ +/- 0.6 % for a temperature variation 60 °C AI2 +/- 0.6 % for a temperature variation 60 °C AO1 +/- 1 % for a temperature variation 60 °C
linearity error
AI1-/Al1+, AI2 +/- 0.15 % of maximum value AO1 +/- 0.2 %
analogue output number
1
analogue output type
AO1 software-configurable current 0…20 mA, impedance 500 Ohm, resolution 10 bits AO1 software-configurable logic output 10 V <= 20 mA AO1 software-configurable voltage 0…10 V DC, impedance 470 Ohm, resolution 10 bits
discrete output number
2
discrete output type
R1A, R1B, R1C configurable relay logic NO/NC, electrical durability 100000 cycles R2A, R2B configurable relay logic NO, electrical durability 100000 cycles
minimum switching current
Configurable relay logic 3 mA at 24 V DC
maximum switching current
R1, R2 on resistive load, 5 A at 250 V AC, cos phi = 1, R1, R2 on resistive load, 5 A at 30 V DC, cos phi = 1, R1, R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4, R1, R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4,
discrete input number
7
discrete input type
LI6 : switch-configurable 24 V DC with level 1 PLC, impedance: 3500 Ohm PWR : safety input 24 V DC, impedance: 1500 Ohm conforming to ISO 13849-1 level d LI1…LI5 : programmable 24 V DC with level 1 PLC, impedance: 3500 Ohm LI6 : switch-configurable PTC probe 0…6, impedance: 1500 Ohm
discrete input logic
LI1…LI5 positive logic (source), < 5 V (state 0), > 11 V (state 0) LI1…LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 0) LI6 (if configured as logic input) positive logic (source), < 5 V (state 0), > 11 V (state 0) LI6 (if configured as logic input) negative logic (sink), > 16 V (state 0), < 10 V (state 0)
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s Automatic adaptation of ramp if braking capacity exceeded, by using resistor S, U or customized
braking to standstill
By DC injection
protection type
Drive against exceeding limit speed Drive against input phase loss Drive break on the control circuit Drive input phase breaks Drive line supply overvoltage Drive line supply undervoltage Drive overcurrent between output phases and earth Drive overheating protection Drive overvoltages on the DC bus Drive short-circuit between motor phases Drive thermal protection Motor motor phase break Motor power removal Motor thermal protection
insulation resistance
> 1 mOhm at 500 V DC for 1 minute to earth
frequency resolution
Analog input 0.024/50 Hz Display unit 0.1 Hz
communication port protocol
CANopen Modbus
connector type
1 RJ45 for Modbus on front face 1 RJ45 for Modbus on terminal Male SUB-D 9 on RJ45 for CANopen
physical interface
2-wire RS 485 for Modbus
transmission frame
RTU for Modbus
transmission rate
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal 9600 bps, 19200 bps for Modbus on front face
data format
8 bits, 1 stop, even parity for Modbus on front face 8 bits, odd even or no configurable parity for Modbus on terminal
number of addresses
1…247 for Modbus 1…127 for CANopen
method of access
Slave for CANopen
marking
CE
operating position
Vertical +/- 10 degree
height
230 mm
depth
175 mm
width
130 mm
product weight
3 kg
functionality
Full
specific application
Other applications
option card
CC-Link communication card Controller inside programmable card DeviceNet communication card Ethernet/IP communication card Fipio communication card I/O extension card Interbus-S communication card Interface card for encoder Modbus Plus communication card Modbus TCP communication card Modbus/Uni-Telway communication card Overhead crane card Profibus DP communication card Profibus DP V1 communication card
Environment
noise level
43 dB conforming to 86/188/EEC
dielectric strength
3535 V DC between earth and power terminals 5092 V DC between control and power terminals
electromagnetic compatibility
Conducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4 Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 1.2/50 µs – 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3
standards
EN/IEC 61800-3 EN 55011 class A group 1 UL Type 1 EN 61800-3 environments 2 category C2 EN/IEC 61800-5-1 IEC 60721-3-3 class 3S2 IEC 60721-3-3 class 3C1 EN 61800-3 environments 1 category C2
product certifications
CSA C-Tick GOST UL NOM 117
pollution degree
2 conforming to EN/IEC 61800-5-1
IP degree of protection
IP20
vibration resistance
1.5 mm peak to peak (f = 3…13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
shock resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3
ambient air temperature for operation
-10…50 °C without derating
ambient air temperature for storage
-25…70 °C
operating altitude
<= 1000 m without derating 1000…3000 m with current derating 1 % per 100 m
,

ATV71HD30M3X383 Schneider drives 30kW -w/o EMC filter 200..240V 3 phases

ATV71HD30M3X383 Schneider drives 30kW – w/o EMC filter-graphic terminal

  • variable speed drive ATV71
  • 30kW-40HP – 240V
  • w/o EMC filter-graphic terminal
Main
range of product
Altivar 71
product or component type
Variable speed drive
product specific application
Complex, high-power machines
component name
ATV71
motor power kW
30 kWat 200…240 V 3 phases
motor power hp
40 hpat 200…240 V 3 phases
motor cable length
<= 656.17 ft (200 m) Unshielded cable <= 328.08 ft (100 m) Shielded cable
[Us] rated supply voltage
200…240 V (- 15…10 %)
Phase
3 phases
line current
110 Afor 240 V 3 phases 30 kW / 40 hp 124 Afor 200 V 3 phases 30 kW / 40 hp
EMC filter
Without EMC filter
assembly style
With heat sink
,

Schneider ATV71HD75M3X variable speed drive ATV71 – 75kW

Schneider ATV71HD75M3X variable speed drive ATV71 – 75kW

Main
range of product
Altivar 71
product or component type
Variable speed drive
product specific application
Complex, high-power machines
component name
ATV71
motor power kW
75 kWat 200…240 V 3 phases
motor power hp
100 hpat 200…240 V 3 phases
motor cable length
<= 328.08 ft (100 m) Shielded cable <= 656.17 ft (200 m) Unshielded cable
[Us] rated supply voltage
200…240 V (- 15…10 %)
Phase
3 phases
line current
232 Afor 240 V 3 phases 75 kW / 100 hp 271 Afor 200 V 3 phases 75 kW / 100 hp
EMC filter
Without EMC filter
assembly style
With heat sink
variant
Reinforced version
apparent power
96.4 kVAat 240 V 3 phases 75 kW / 100 hp
prospective line Isc
<= 35 kA, 3 phases
nominal output current
285 Aat 2.5 kHz 230 V 3 phases 75 kW / 100 hp
,

Schneider drives VFD ATV71HC25N4D 220KW 480V

range of product
Altivar 71
product or component type
Variable speed drive
product specific application
Complex, high-power machines
component name
ATV71
motor power kW
220 kW, 3 phase 380…480 V
250 kW, 3 phase 380…480 V
Maximum Horse Power Rating
350 hp, 3 phase 380…480 V
400 hp, 3 phase 380…480 V
maximum motor cable length
328.08 ft (100 m) shielded cable
656.17 ft (200 m) unshielded cable
power supply voltage
380…480 V – 15…10 %
Phase
3 phase
line current
320 A 480 V 3 phase 220 kW / 350 hp
357 A 480 V 3 phase 250 kW / 400 hp
396 A 380 V 3 phase 220 kW / 350 hp
444 A 380 V 3 phase 250 kW / 400 hp
EMC filter
Integrated
assembly style
With heat sink
variant
Without DC choke
Reinforced version
apparent power
260.6 kVA 380 V 3 phase 220 kW / 350 hp
292.2 kVA 380 V 3 phase 250 kW / 400 hp
prospective line Isc
50 kA 3 phase
nominal output current
427 A 2.5 kHz 380 V 3 phase 220 kW / 350 hp
427 A 2.5 kHz 460 V 3 phase 220 kW / 350 hp
481 A 2.5 kHz 380 V 3 phase 250 kW / 400 hp
481 A 2.5 kHz 460 V 3 phase 250 kW / 400 hp
maximum transient current
640 A 60 s 3 phase 220 kW / 350 hp
704 A 2 s 3 phase 220 kW / 350 hp
721 A 60 s 3 phase 250 kW / 400 hp
793 A 2 s 3 phase 250 kW / 400 hp
output frequency
0.1…500 Hz
nominal switching frequency
2.5 kHz
switching frequency
2.5…8 kHz adjustable
2.5…8 kHz with derating factor
asynchronous motor control profile
Sensorless flux vector control (SFVC) (voltage or current vector)
Flux vector control (FVC) with sensor (current vector)
Voltage/frequency ratio (2 or 5 points)
ENA (Energy adaptation) system for unbalanced loads
type of polarization
No impedance Modbus
Maximum Height
46.85 in (1190 mm)
Maximum Depth
14.84 in (377 mm)
Maximum Width
23.43 in (595 mm)
Net Weight
308.65 lb(US) (140 kg)
,

ATV71HD45Y Schneider variable speed drive ATV71 – 45kW – 690V

Variable speed drive ATV71 – 45kW – 690V – EMC filter-graphic terminal

range of product

Altivar 71

product or component type

Variable speed drive

product specific application

Complex, high-power machines

component name

ATV71

motor power kW

37 kW, 3 phase 500 V

45 kW, 3 phase 690 V

Maximum Horse Power Rating

50 hp, 3 phase 575 V

maximum motor cable length

32.81 ft (10 m) shielded cable

32.81 ft (10 m) unshielded cable

power supply voltage

500…690 V – 15…10 %

Phase

3 phase

line current

51 A 600 V 3 phase / 50 hp

55 A 690 V 3 phase 45 kW

62 A 500 V 3 phase 37 kW

EMC filter

Integrated

assembly style

With heat sink

variant

Reinforced version

prospective line Isc

22 kA 3 phase

nominal output current

52 A 2.5 kHz 575 V 3 phase / 50 hp

54 A 2.5 kHz 690 V 3 phase 45 kW

59 A 2.5 kHz 500 V 3 phase 37 kW

maximum transient current

88.5 A 60 s 3 phase 37 kW

97.35 A 2 s 3 phase / 50 hp

97.35 A 2 s 3 phase 45 kW

output frequency

0.1…500 Hz

nominal switching frequency

2.5 kHz

switching frequency

2.5…4.9 kHz adjustable

2.5…4.9 kHz with derating factor

asynchronous motor control profile

ENA (Energy adaptation) system for unbalanced loads

Voltage/frequency ratio (2 or 5 points)

Flux vector control (FVC) with sensor (current vector)

Sensorless flux vector control (SFVC) (voltage or current vector)

type of polarization

No impedance Modbus

Complementary

product destination

Synchronous motors

Asynchronous motors

power supply voltage limits

425…759 V

power supply frequency

50…60 Hz – 5…5 %

power supply frequency limits

47.5…63 Hz

speed range

1…100 asynchronous motor in open-loop mode, without speed feedback

1…1000 asynchronous motor in closed-loop mode with encoder feedback

1…50 synchronous motor in open-loop mode, without speed feedback

speed accuracy

+/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn

+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn

torque accuracy

+/- 15 % in open-loop mode, without speed feedback

+/- 5 % in closed-loop mode with encoder feedback

transient overtorque

170 % +/- 10 % 60 s every 10 minutes

220 % +/- 10 % 2 s

braking torque

<= 150 % with braking or hoist resistor

30 % without braking resistor

synchronous motor control profile

Vector control without speed feedback

regulation loop

Adjustable PI regulator

motor slip compensation

Not available in voltage/frequency ratio (2 or 5 points)

Adjustable

Suppressable

Automatic whatever the load

diagnostic

Drive voltage 1 LED red)

output voltage

<= power supply voltage

insulation

Electrical between power and control

type of cable for mounting in an enclosure

With a NEMA Type1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC

With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC

Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC

Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR

electrical connection

Terminal 2.5 mm², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)

Terminal 150 mm² L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)

tightening torque

5.31 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)

362.88 lbf.in (41 N.m), 360 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)

supply

Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection

Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection

analogue input number

2

analogue input type

AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign

AI2 software-configurable current 0…20 mA 242 Ohm 11 bits

AI2 software-configurable voltage 0…10 V DC 24 V max 30000 Ohm 11 bits

input sampling time

2 ms +/- 0.5 ms AI1-/Al1+) – analog

2 ms +/- 0.5 ms Al2) – analog

2 ms +/- 0.5 ms LI1…LI5) – discrete

2 ms +/- 0.5 ms LI6)if configured as logic input – discrete

response time

<= 100 ms in STO (Safe Torque Off)

AO1 2 ms +/- 0.5 ms analog

R1A, R1B, R1C 7 ms +/- 0.5 ms discrete

R2A, R2B 7 ms +/- 0.5 ms discrete

absolute accuracy precision

+/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C

+/- 0.6 % AI2) for a temperature variation 60 °C

+/- 1 % AO1) for a temperature variation 60 °C

linearity error

+/- 0.15 % of maximum value AI1-/Al1+, AI2)

+/- 0.2 % AO1)

analogue output number

1

analogue output type

AO1 software-configurable logic output 10 V 20 mA

AO1 software-configurable current 0…20 mA 500 Ohm 10 bits

AO1 software-configurable voltage 0…10 V DC 470 Ohm 10 bits

discrete output number

2

discrete output type

Configurable relay logic R1A, R1B, R1C) NO/NC – 100000 cycles

Configurable relay logic R2A, R2B) NO – 100000 cycles

minimum switching current

3 mA 24 V DC configurable relay logic

maximum switching current

R1, R2 2 A 250 V AC inductive, cos phi = 0.4

R1, R2 2 A 30 V DC inductive, cos phi = 0.4

R1, R2 5 A 250 V AC resistive, cos phi = 1

R1, R2 5 A 30 V DC resistive, cos phi = 1

discrete input number

7

discrete input type

LI1…LI5 programmable 24 V DC level 1 PLC 3500 Ohm

LI6 switch-configurable 24 V DC level 1 PLC 3500 Ohm

LI6 switch-configurable PTC probe 0…6 1500 Ohm

PWR safety input 24 V DC 1500 Ohm ISO 13849-1 level d

discrete input logic

Negative logic (sink) LI1…LI5), > 16 V, < 10 V

Positive logic (source) LI1…LI5), < 5 V, > 11 V

Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V

Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V

acceleration and deceleration ramps

S, U or customized

Linear adjustable separately from 0.01 to 9000 s

Automatic adaptation of ramp if braking capacity exceeded, by using resistor

braking to standstill

By DC injection

protection type

Against exceeding limit speed drive

Against input phase loss drive

Break on the control circuit drive

Input phase breaks drive

Line supply overvoltage drive

Line supply undervoltage drive

Overcurrent between output phases and earth drive

Overheating protection drive

Overvoltages on the DC bus drive

Short-circuit between motor phases drive

Thermal protection drive

Motor phase break motor

Power removal motor

Thermal protection motor

insulation resistance

> 1 mOhm 500 V DC for 1 minute to earth

frequency resolution

Analog input 0.024/50 Hz

Display unit 0.1 Hz

communication port protocol

Modbus

CANopen

connector type

1 RJ45 on front face)Modbus

1 RJ45 on terminal)Modbus

Male SUB-D 9 on RJ45CANopen

physical interface

2-wire RS 485 Modbus

transmission frame

RTU Modbus

transmission rate

4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal

9600 bps, 19200 bps Modbus on front face

20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen

data format

8 bits, 1 stop, even parity Modbus on front face

8 bits, odd even or no configurable parity Modbus on terminal

number of addresses

1…127 CANopen

1…247 Modbus

method of access

Slave CANopen

marking

CE

operating position

Vertical +/- 10 degree

height

24.80 in (630 mm)

depth

11.42 in (290 mm)

width

12.60 in (320 mm)

product weight

149.91 lb(US) (68 kg)

option card

Communication card CC-Link

Controller inside programmable card

Communication card DeviceNet

Communication card Ethernet/IP

Communication card Fipio

I/O extension card

Communication card Interbus-S

Interface card for encoder

Communication card Modbus Plus

Communication card Modbus TCP

Communication card Modbus/Uni-Telway

Overhead crane card

Communication card Profibus DP

Communication card Profibus DP V1

Environment

noise level

63.7 dB 86/188/EEC

dielectric strength

3110 V DC between earth and power terminals

5345 V DC between control and power terminals

electromagnetic compatibility

1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5

Conducted radio-frequency immunity test level 3 IEC 61000-4-6

Electrical fast transient/burst immunity test level 4 IEC 61000-4-4

Electrostatic discharge immunity test level 3 IEC 61000-4-2

Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3

Voltage dips and interruptions immunity test IEC 61000-4-11

standards

UL Type 1

EN 61800-3 environments 1 category C3

EN/IEC 61800-3

EN/IEC 61800-5-1

EN 61800-3 environments 2 category C3

EN 55011 class A group 2

IEC 60721-3-3 class 3C2

product certifications

CSA

UL

GOST

C-Tick

NOM 117

pollution degree

2 EN/IEC 61800-5-1

3 UL 840

IP degree of protection

IP20 on upper part without blanking plate on cover EN/IEC 60529

IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1

IP21 EN/IEC 60529

IP21 EN/IEC 61800-5-1

IP41 on upper part EN/IEC 60529

IP41 on upper part EN/IEC 61800-5-1

IP54 on lower part EN/IEC 60529

IP54 on lower part EN/IEC 61800-5-1

vibration resistance

1 gn 13…200 Hz)EN/IEC 60068-2-6

1.5 mm peak to peak 3…13 Hz)EN/IEC 60068-2-6

shock resistance

15 gn 11 ms EN/IEC 60068-2-27

relative humidity

5…95 % without condensation IEC 60068-2-3

5…95 % without dripping water IEC 60068-2-3

ambient air temperature for operation

14…122 °F (-10…50 °C) without)

ambient air temperature for storage

-13…158 °F (-25…70 °C)

operating altitude

<= 3280.84 ft (1000 m) without

3280.84…7414.7 ft (1000…2260 m) with current derating 1 % per 100 m

Ordering and shipping details

Category

22131 – ATV71 – 7.5 THRU 50HP

Discount Schedule

CP4C

GTIN

785901443131

Package weight(Lbs)

68.04 kg (150 lb(US))

Returnability

No

Country of origin

FR

Offer Sustainability

Sustainable offer status

Green Premium product

California proposition 65

WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov

REACh Regulation

REACh Declaration

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

EU RoHS Declaration

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declaration

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

,

Schneider variable speed drive ATV71HD90N4 90kW-125HP – 480V – EMC filter

Variable speed drive ATV71 – 90kW-125HP – 480V – EMC filter-graphic terminal

range of product

Altivar 71

product or component type

Variable speed drive

product specific application

Complex, high-power machines

component name

ATV71

motor power kW

90 kW, 3 phase 380…480 V

Maximum Horse Power Rating

125 hp, 3 phase 380…480 V

maximum motor cable length

328.08 ft (100 m) shielded cable

656.17 ft (200 m) unshielded cable

power supply voltage

380…480 V – 15…10 %

Phase

3 phase

line current

134 A 480 V 3 phase 90 kW / 125 hp

166 A 380 V 3 phase 90 kW / 125 hp

EMC filter

Integrated

assembly style

With heat sink

variant

Reinforced version

apparent power

109.3 kVA 380 V 3 phase 90 kW / 125 hp

prospective line Isc

35 kA 3 phase

nominal output current

179 A 2.5 kHz 380 V 3 phase 90 kW / 125 hp

179 A 2.5 kHz 460 V 3 phase 90 kW / 125 hp

maximum transient current

269 A 60 s 3 phase 90 kW / 125 hp

295 A 2 s 3 phase 90 kW / 125 hp

output frequency

0.1…500 Hz

nominal switching frequency

2.5 kHz

switching frequency

2.5…8 kHz adjustable

2.5…8 kHz with derating factor

asynchronous motor control profile

Voltage/frequency ratio (2 or 5 points)

Sensorless flux vector control (SFVC) (voltage or current vector)

Flux vector control (FVC) with sensor (current vector)

ENA (Energy adaptation) system for unbalanced loads

type of polarization

No impedance Modbus

Complementary

product destination

Asynchronous motors

Synchronous motors

power supply voltage limits

323…528 V

power supply frequency

50…60 Hz – 5…5 %

power supply frequency limits

47.5…63 Hz

speed range

1…100 asynchronous motor in open-loop mode, without speed feedback

1…1000 asynchronous motor in closed-loop mode with encoder feedback

1…50 synchronous motor in open-loop mode, without speed feedback

speed accuracy

+/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn

+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn

torque accuracy

+/- 15 % in open-loop mode, without speed feedback

+/- 5 % in closed-loop mode with encoder feedback

transient overtorque

170 % +/- 10 % 60 s every 10 minutes

220 % +/- 10 % 2 s

braking torque

<= 150 % with braking or hoist resistor

30 % without braking resistor

synchronous motor control profile

Vector control without speed feedback

regulation loop

Adjustable PI regulator

motor slip compensation

Suppressable

Not available in voltage/frequency ratio (2 or 5 points)

Automatic whatever the load

Adjustable

diagnostic

Drive voltage 1 LED red)

output voltage

<= power supply voltage

insulation

Electrical between power and control

type of cable for mounting in an enclosure

With a NEMA Type1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC

With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC

Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC

Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR

electrical connection

Terminal 2.5 mm², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)

Terminal 2 x 100 mm² L1/R, L2/S, L3/T, U/T1, V/T2, W/T3)

Terminal 60 mm² PA, PB)

Terminal 2 x 100 mm² PC/-, PO, PA/+)

tightening torque

5.31 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)

212.42 lbf.in (24 N.m), 212 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3)

106.21 lbf.in (12 N.m), 106 lb.in PA, PB)

362.88 lbf.in (41 N.m), 360 lb.in PC/-, PO, PA/+)

supply

Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection

Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection

analogue input number

2

analogue input type

AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign

AI2 software-configurable current 0…20 mA 242 Ohm 11 bits

AI2 software-configurable voltage 0…10 V DC 24 V max 30000 Ohm 11 bits

input sampling time

2 ms +/- 0.5 ms AI1-/Al1+) – analog

2 ms +/- 0.5 ms Al2) – analog

2 ms +/- 0.5 ms LI1…LI5) – discrete

2 ms +/- 0.5 ms LI6)if configured as logic input – discrete

response time

<= 100 ms in STO (Safe Torque Off)

AO1 2 ms +/- 0.5 ms analog

R1A, R1B, R1C 7 ms +/- 0.5 ms discrete

R2A, R2B 7 ms +/- 0.5 ms discrete

absolute accuracy precision

+/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C

+/- 0.6 % AI2) for a temperature variation 60 °C

+/- 1 % AO1) for a temperature variation 60 °C

linearity error

+/- 0.15 % of maximum value AI1-/Al1+, AI2)

+/- 0.2 % AO1)

analogue output number

1

analogue output type

AO1 software-configurable logic output 10 V 20 mA

AO1 software-configurable current 0…20 mA 500 Ohm 10 bits

AO1 software-configurable voltage 0…10 V DC 470 Ohm 10 bits

discrete output number

2

discrete output type

Configurable relay logic R1A, R1B, R1C) NO/NC – 100000 cycles

Configurable relay logic R2A, R2B) NO – 100000 cycles

minimum switching current

3 mA 24 V DC configurable relay logic

maximum switching current

R1, R2 2 A 250 V AC inductive, cos phi = 0.4

R1, R2 2 A 30 V DC inductive, cos phi = 0.4

R1, R2 5 A 250 V AC resistive, cos phi = 1

R1, R2 5 A 30 V DC resistive, cos phi = 1

discrete input number

7

discrete input type

LI1…LI5 programmable 24 V DC level 1 PLC 3500 Ohm

LI6 switch-configurable 24 V DC level 1 PLC 3500 Ohm

LI6 switch-configurable PTC probe 0…6 1500 Ohm

PWR safety input 24 V DC 1500 Ohm ISO 13849-1 level d

discrete input logic

Negative logic (sink) LI1…LI5), > 16 V, < 10 V

Positive logic (source) LI1…LI5), < 5 V, > 11 V

Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V

Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V

acceleration and deceleration ramps

Automatic adaptation of ramp if braking capacity exceeded, by using resistor

Linear adjustable separately from 0.01 to 9000 s

S, U or customized

braking to standstill

By DC injection

protection type

Against exceeding limit speed drive

Against input phase loss drive

Break on the control circuit drive

Input phase breaks drive

Line supply overvoltage drive

Line supply undervoltage drive

Overcurrent between output phases and earth drive

Overheating protection drive

Overvoltages on the DC bus drive

Short-circuit between motor phases drive

Thermal protection drive

Motor phase break motor

Power removal motor

Thermal protection motor

insulation resistance

> 1 mOhm 500 V DC for 1 minute to earth

frequency resolution

Analog input 0.024/50 Hz

Display unit 0.1 Hz

communication port protocol

Modbus

CANopen

connector type

1 RJ45 on front face)Modbus

1 RJ45 on terminal)Modbus

Male SUB-D 9 on RJ45CANopen

physical interface

2-wire RS 485 Modbus

transmission frame

RTU Modbus

transmission rate

4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal

9600 bps, 19200 bps Modbus on front face

20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen

data format

8 bits, 1 stop, even parity Modbus on front face

8 bits, odd even or no configurable parity Modbus on terminal

number of addresses

1…127 CANopen

1…247 Modbus

method of access

Slave CANopen

marking

CE

operating position

Vertical +/- 10 degree

height

36.22 in (920 mm)

depth

14.84 in (377 mm)

width

12.60 in (320 mm)

product weight

220.46 lb(US) (100 kg)

functionality

Full

specific application

Other applications

option card

Communication card CC-Link

Controller inside programmable card

Communication card DeviceNet

Communication card Ethernet/IP

Communication card Fipio

I/O extension card

Communication card Interbus-S

Interface card for encoder

Communication card Modbus Plus

Communication card Modbus TCP

Communication card Modbus/Uni-Telway

Overhead crane card

Communication card Profibus DP

Communication card Profibus DP V1

Environment

noise level

60.5 dB 86/188/EEC

dielectric strength

3535 V DC between earth and power terminals

5092 V DC between control and power terminals

electromagnetic compatibility

1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5

Conducted radio-frequency immunity test level 3 IEC 61000-4-6

Electrical fast transient/burst immunity test level 4 IEC 61000-4-4

Electrostatic discharge immunity test level 3 IEC 61000-4-2

Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3

Voltage dips and interruptions immunity test IEC 61000-4-11

standards

EN/IEC 61800-5-1

EN 55011 class A group 2

EN 61800-3 environments 2 category C3

IEC 60721-3-3 class 3C2

UL Type 1

EN 61800-3 environments 1 category C3

EN/IEC 61800-3

product certifications

GOST

NOM 117

C-Tick

CSA

UL

pollution degree

2 EN/IEC 61800-5-1

3 UL 840

IP degree of protection

IP20

vibration resistance

0.6 gn 10…200 Hz)EN/IEC 60068-2-6

1.5 mm peak to peak 3…10 Hz)EN/IEC 60068-2-6

shock resistance

7 gn 11 ms EN/IEC 60068-2-27

relative humidity

5…95 % without condensation IEC 60068-2-3

5…95 % without dripping water IEC 60068-2-3

ambient air temperature for operation

14…122 °F (-10…50 °C) without)

ambient air temperature for storage

-13…158 °F (-25…70 °C)

operating altitude

<= 3280.84 ft (1000 m) without

3280.84…9842.52 ft (1000…3000 m) with current derating 1 % per 100 m

,

ATV71HD45N4 Schneider variable speed driv ATV71 55KW 480V AC Drives

ATV71HD45N4 Schneider variable speed drive ATV71 AC DRIVE AC Inverters, variable speed drive ATV71 – 45kW-60HP – 480V – EMC filter-graphic terminal