Schneider variable speed drive ATV71 – 160kW ATV71HC16N4D

Schneider variable speed drive ATV71 – 160kW ATV71HC16N4D

  • Altivar 71 Variable Frequency Drives VFD
range of product
Altivar 71
product or component type
Variable speed drive
product specific application
Complex, high-power machines
component name
ATV71
motor power kW
160 kWat 380…480 V 3 phases
motor power hp
250 hpat 380…480 V 3 phases
motor cable length
<= 328.08 ft (100 m) Shielded cable <= 656.17 ft (200 m) Unshielded cable
[Us] rated supply voltage
380…480 V (- 15…10 %)
Phase
3 phases
line current
233 Afor 480 V 3 phases 160 kW / 250 hp 289 Afor 380 V 3 phases 160 kW / 250 hp
EMC filter
Integrated
assembly style
With heat sink
variant
Reinforced version Without DC choke
apparent power
190.2 kVAat 380 V 3 phases 160 kW / 250 hp
prospective line Isc
<= 50 kA, 3 phases
nominal output current
314 Aat 2.5 kHz 380 V 3 phases 160 kW / 250 hp 314 Aat 2.5 kHz 460 V 3 phases 160 kW / 250 hp
maximum transient current
471 Afor 60 s 3 phases 160 kW / 250 hp 518 Afor 2 s 3 phases 160 kW / 250 hp
output frequency
0.1…500 Hz
nominal switching frequency
2.5 kHz
switching frequency
2.5…8 kHz adjustable 2.5…8 kHz with derating factor
asynchronous motor control profile
Sensorless flux vector control (SFVC) (voltage or current vector) ENA (Energy adaptation) system for unbalanced loads Voltage/frequency ratio (2 or 5 points) Flux vector control (FVC) with sensor (current vector)
,

Schneider ATV61HD75N4S337 variable speed drive ATV61 – 75kW

Schneider ATV61HD75N4S337 variable speed drive ATV61 – 75kW

  • variable speed drive ATV61
  • 75kW 100HP – 380…480V
  • IP20 – reinforced
Main
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
75 kW 3 phasesat 380…480 V
motor power hp
100 hp 3 phasesat 380…480 V
[Us] rated supply voltage
380…480 V (- 15…10 %)
Phase
3 phases
line current
137 Afor 480 V 3 phases 75 kW / 100 hp 167 Afor 380 V 3 phases 75 kW / 100 hp
EMC filter
Level 3 EMC filter
variant
Reinforced version
assembly style
With heat sink
apparent power
109.9 kVAfor 380 V 3 phases 75 kW / 100 hp
prospective line Isc
22 kA 3 phases
maximum transient current
192 A for 60 s 3 phases
nominal switching frequency
12 kHz
switching frequency
1…16 kHz adjustable 12…16 kHz with derating factor
asynchronous motor control profile
Voltage/frequency ratio, 2 points Flux vector control without sensor, standard Voltage/frequency ratio – Energy Saving, quadratic U/f Voltage/frequency ratio, 5 points
synchronous motor control profile
Vector control without sensor, standard
,

ATV71HD45Y Schneider variable speed drive ATV71 – 45kW – 690V

Variable speed drive ATV71 – 45kW – 690V – EMC filter-graphic terminal

range of product

Altivar 71

product or component type

Variable speed drive

product specific application

Complex, high-power machines

component name

ATV71

motor power kW

37 kW, 3 phase 500 V

45 kW, 3 phase 690 V

Maximum Horse Power Rating

50 hp, 3 phase 575 V

maximum motor cable length

32.81 ft (10 m) shielded cable

32.81 ft (10 m) unshielded cable

power supply voltage

500…690 V – 15…10 %

Phase

3 phase

line current

51 A 600 V 3 phase / 50 hp

55 A 690 V 3 phase 45 kW

62 A 500 V 3 phase 37 kW

EMC filter

Integrated

assembly style

With heat sink

variant

Reinforced version

prospective line Isc

22 kA 3 phase

nominal output current

52 A 2.5 kHz 575 V 3 phase / 50 hp

54 A 2.5 kHz 690 V 3 phase 45 kW

59 A 2.5 kHz 500 V 3 phase 37 kW

maximum transient current

88.5 A 60 s 3 phase 37 kW

97.35 A 2 s 3 phase / 50 hp

97.35 A 2 s 3 phase 45 kW

output frequency

0.1…500 Hz

nominal switching frequency

2.5 kHz

switching frequency

2.5…4.9 kHz adjustable

2.5…4.9 kHz with derating factor

asynchronous motor control profile

ENA (Energy adaptation) system for unbalanced loads

Voltage/frequency ratio (2 or 5 points)

Flux vector control (FVC) with sensor (current vector)

Sensorless flux vector control (SFVC) (voltage or current vector)

type of polarization

No impedance Modbus

Complementary

product destination

Synchronous motors

Asynchronous motors

power supply voltage limits

425…759 V

power supply frequency

50…60 Hz – 5…5 %

power supply frequency limits

47.5…63 Hz

speed range

1…100 asynchronous motor in open-loop mode, without speed feedback

1…1000 asynchronous motor in closed-loop mode with encoder feedback

1…50 synchronous motor in open-loop mode, without speed feedback

speed accuracy

+/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn

+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn

torque accuracy

+/- 15 % in open-loop mode, without speed feedback

+/- 5 % in closed-loop mode with encoder feedback

transient overtorque

170 % +/- 10 % 60 s every 10 minutes

220 % +/- 10 % 2 s

braking torque

<= 150 % with braking or hoist resistor

30 % without braking resistor

synchronous motor control profile

Vector control without speed feedback

regulation loop

Adjustable PI regulator

motor slip compensation

Not available in voltage/frequency ratio (2 or 5 points)

Adjustable

Suppressable

Automatic whatever the load

diagnostic

Drive voltage 1 LED red)

output voltage

<= power supply voltage

insulation

Electrical between power and control

type of cable for mounting in an enclosure

With a NEMA Type1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC

With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC

Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC

Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR

electrical connection

Terminal 2.5 mm², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)

Terminal 150 mm² L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)

tightening torque

5.31 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)

362.88 lbf.in (41 N.m), 360 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)

supply

Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection

Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection

analogue input number

2

analogue input type

AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign

AI2 software-configurable current 0…20 mA 242 Ohm 11 bits

AI2 software-configurable voltage 0…10 V DC 24 V max 30000 Ohm 11 bits

input sampling time

2 ms +/- 0.5 ms AI1-/Al1+) – analog

2 ms +/- 0.5 ms Al2) – analog

2 ms +/- 0.5 ms LI1…LI5) – discrete

2 ms +/- 0.5 ms LI6)if configured as logic input – discrete

response time

<= 100 ms in STO (Safe Torque Off)

AO1 2 ms +/- 0.5 ms analog

R1A, R1B, R1C 7 ms +/- 0.5 ms discrete

R2A, R2B 7 ms +/- 0.5 ms discrete

absolute accuracy precision

+/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C

+/- 0.6 % AI2) for a temperature variation 60 °C

+/- 1 % AO1) for a temperature variation 60 °C

linearity error

+/- 0.15 % of maximum value AI1-/Al1+, AI2)

+/- 0.2 % AO1)

analogue output number

1

analogue output type

AO1 software-configurable logic output 10 V 20 mA

AO1 software-configurable current 0…20 mA 500 Ohm 10 bits

AO1 software-configurable voltage 0…10 V DC 470 Ohm 10 bits

discrete output number

2

discrete output type

Configurable relay logic R1A, R1B, R1C) NO/NC – 100000 cycles

Configurable relay logic R2A, R2B) NO – 100000 cycles

minimum switching current

3 mA 24 V DC configurable relay logic

maximum switching current

R1, R2 2 A 250 V AC inductive, cos phi = 0.4

R1, R2 2 A 30 V DC inductive, cos phi = 0.4

R1, R2 5 A 250 V AC resistive, cos phi = 1

R1, R2 5 A 30 V DC resistive, cos phi = 1

discrete input number

7

discrete input type

LI1…LI5 programmable 24 V DC level 1 PLC 3500 Ohm

LI6 switch-configurable 24 V DC level 1 PLC 3500 Ohm

LI6 switch-configurable PTC probe 0…6 1500 Ohm

PWR safety input 24 V DC 1500 Ohm ISO 13849-1 level d

discrete input logic

Negative logic (sink) LI1…LI5), > 16 V, < 10 V

Positive logic (source) LI1…LI5), < 5 V, > 11 V

Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V

Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V

acceleration and deceleration ramps

S, U or customized

Linear adjustable separately from 0.01 to 9000 s

Automatic adaptation of ramp if braking capacity exceeded, by using resistor

braking to standstill

By DC injection

protection type

Against exceeding limit speed drive

Against input phase loss drive

Break on the control circuit drive

Input phase breaks drive

Line supply overvoltage drive

Line supply undervoltage drive

Overcurrent between output phases and earth drive

Overheating protection drive

Overvoltages on the DC bus drive

Short-circuit between motor phases drive

Thermal protection drive

Motor phase break motor

Power removal motor

Thermal protection motor

insulation resistance

> 1 mOhm 500 V DC for 1 minute to earth

frequency resolution

Analog input 0.024/50 Hz

Display unit 0.1 Hz

communication port protocol

Modbus

CANopen

connector type

1 RJ45 on front face)Modbus

1 RJ45 on terminal)Modbus

Male SUB-D 9 on RJ45CANopen

physical interface

2-wire RS 485 Modbus

transmission frame

RTU Modbus

transmission rate

4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal

9600 bps, 19200 bps Modbus on front face

20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen

data format

8 bits, 1 stop, even parity Modbus on front face

8 bits, odd even or no configurable parity Modbus on terminal

number of addresses

1…127 CANopen

1…247 Modbus

method of access

Slave CANopen

marking

CE

operating position

Vertical +/- 10 degree

height

24.80 in (630 mm)

depth

11.42 in (290 mm)

width

12.60 in (320 mm)

product weight

149.91 lb(US) (68 kg)

option card

Communication card CC-Link

Controller inside programmable card

Communication card DeviceNet

Communication card Ethernet/IP

Communication card Fipio

I/O extension card

Communication card Interbus-S

Interface card for encoder

Communication card Modbus Plus

Communication card Modbus TCP

Communication card Modbus/Uni-Telway

Overhead crane card

Communication card Profibus DP

Communication card Profibus DP V1

Environment

noise level

63.7 dB 86/188/EEC

dielectric strength

3110 V DC between earth and power terminals

5345 V DC between control and power terminals

electromagnetic compatibility

1.2/50 µs – 8/20 µs surge immunity test level 3 IEC 61000-4-5

Conducted radio-frequency immunity test level 3 IEC 61000-4-6

Electrical fast transient/burst immunity test level 4 IEC 61000-4-4

Electrostatic discharge immunity test level 3 IEC 61000-4-2

Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3

Voltage dips and interruptions immunity test IEC 61000-4-11

standards

UL Type 1

EN 61800-3 environments 1 category C3

EN/IEC 61800-3

EN/IEC 61800-5-1

EN 61800-3 environments 2 category C3

EN 55011 class A group 2

IEC 60721-3-3 class 3C2

product certifications

CSA

UL

GOST

C-Tick

NOM 117

pollution degree

2 EN/IEC 61800-5-1

3 UL 840

IP degree of protection

IP20 on upper part without blanking plate on cover EN/IEC 60529

IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1

IP21 EN/IEC 60529

IP21 EN/IEC 61800-5-1

IP41 on upper part EN/IEC 60529

IP41 on upper part EN/IEC 61800-5-1

IP54 on lower part EN/IEC 60529

IP54 on lower part EN/IEC 61800-5-1

vibration resistance

1 gn 13…200 Hz)EN/IEC 60068-2-6

1.5 mm peak to peak 3…13 Hz)EN/IEC 60068-2-6

shock resistance

15 gn 11 ms EN/IEC 60068-2-27

relative humidity

5…95 % without condensation IEC 60068-2-3

5…95 % without dripping water IEC 60068-2-3

ambient air temperature for operation

14…122 °F (-10…50 °C) without)

ambient air temperature for storage

-13…158 °F (-25…70 °C)

operating altitude

<= 3280.84 ft (1000 m) without

3280.84…7414.7 ft (1000…2260 m) with current derating 1 % per 100 m

Ordering and shipping details

Category

22131 – ATV71 – 7.5 THRU 50HP

Discount Schedule

CP4C

GTIN

785901443131

Package weight(Lbs)

68.04 kg (150 lb(US))

Returnability

No

Country of origin

FR

Offer Sustainability

Sustainable offer status

Green Premium product

California proposition 65

WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov

REACh Regulation

REACh Declaration

EU RoHS Directive

Pro-active compliance (Product out of EU RoHS legal scope)

EU RoHS Declaration

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declaration

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

,

ATV61HC40N4D Schneider ATV61 drives 400KW 3P,380VAC

range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
355 kW, 3 phase 380…480 V
400 kW, 3 phase 380…480 V
Maximum Horse Power Rating
600 hp, 3 phase 380…480 V
power supply voltage
380…480 V – 15…10 %
supply number of phases
3 phase
line current
597 A 480 V 3 phase 355 kW
637 A 380 V 3 phase 355 kW
644 A 480 V 3 phase 400 kW / 600 hp
709 A 380 V 3 phase 400 kW / 600 hp
EMC filter
Level 3 EMC filter
variant
Without DC choke
assembly style
With heat sink
apparent power
419.3 kVA 380 V 3 phase 355 kW
466.6 kVA 380 V 3 phase 400 kW / 600 hp
maximum prospective line Isc
50 kA 3 phase
maximum transient current
910.8 A 60 s, 3 phase
nominal switching frequency
2.5 kHz
switching frequency
2…8 kHz adjustable
2.5…8 kHz with derating factor
asynchronous motor control
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 2 points
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
Modbus
CANopen
type of polarization
No impedance Modbus
,

ATV61HC16N4 SCHNEIDER SPEEDDRIVE,250HP,460V,ATV61

range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
160 kW, 3 phase 380…480 V
Maximum Horse Power Rating
250 hp, 3 phase 380…480 V
power supply voltage
380…480 V – 15…10 %
supply number of phases
3 phase
line current
275 A 480 V 3 phase 160 kW / 250 hp
289 A 380 V 3 phase 160 kW / 250 hp
EMC filter
Level 3 EMC filter
assembly style
With heat sink
apparent power
190.2 kVA 380 V 3 phase 160 kW / 250 hp
maximum prospective line Isc
50 kA 3 phase
maximum transient current
376.8 A 60 s, 3 phase
nominal switching frequency
2.5 kHz
switching frequency
2…8 kHz adjustable
2.5…8 kHz with derating factor
asynchronous motor control
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 points
Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
CANopen
Modbus
type of polarization
No impedance Modbus
,

Schneider Variable speed drives ATV61HC16N4D 160kW, 3 phase 380…480 V

range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
160 kW, 3 phase 380…480 V
Maximum Horse Power Rating
250 hp, 3 phase 380…480 V
power supply voltage
380…480 V – 15…10 %
supply number of phases
3 phase
line current
275 A 480 V 3 phase 160 kW / 250 hp
289 A 380 V 3 phase 160 kW / 250 hp
EMC filter
Level 3 EMC filter
assembly style
With heat sink
apparent power
190.2 kVA 380 V 3 phase 160 kW / 250 hp
maximum prospective line Isc
50 kA 3 phase
maximum transient current
376.8 A 60 s, 3 phase
nominal switching frequency
2.5 kHz
switching frequency
2…8 kHz adjustable
2.5…8 kHz with derating factor
asynchronous motor control
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 points
Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
CANopen
Modbus
,

ATV61HC31N4D Schneider Altivar 61 SPEED DRIVE 500HP,460V

ATV61HC31N4D Schneider Altivar 61 SPEED DRIVE 500HP,460V

Characteristics

Main
range of product
Altivar 61
product or component type
Variable speed drive
product specific application
Pumping and ventilation machine
component name
ATV61
motor power kW
280 kW 3 phasesat 380…480 V 315 kW 3 phasesat 380…480 V
motor power hp
450 hp 3 phasesat 380…480 V 500 hp 3 phasesat 380…480 V
[Us] rated supply voltage
380…480 V (- 15…10 %)
Phase
3 phases
line current
494 Afor 380 V 3 phases 280 kW / 450 hp 494 Afor 480 V 3 phases 280 kW / 450 hp 544 Afor 480 V 3 phases 315 kW / 500 hp 555 Afor 380 V 3 phases 315 kW / 500 hp
EMC filter
Level 3 EMC filter
variant
Without DC choke
assembly style
With heat sink
apparent power
325.1 kVAfor 380 V 3 phases 280 kW / 450 hp 365.3 kVAfor 380 V 3 phases 315 kW / 500 hp
prospective line Isc
50 kA 3 phases
maximum transient current
739.2 Afor 60 s 3 phases
nominal switching frequency
2.5 kHz
switching frequency
2…8 kHz adjustable 2.5…8 kHz with derating factor
asynchronous motor control profile
Voltage/frequency ratio, 5 points Voltage/frequency ratio – Energy Saving, quadratic U/f Voltage/frequency ratio, 2 points Flux vector control without sensor, standard
synchronous motor control profile
Vector control without sensor, standard
communication port protocol
Modbus CANopen
type of polarization
No impedance Modbus
,

ATV61HC63N4 630kW 900HP – 380…480V – IP20

ATV61HC63N4D Altivar 61  Variable speed drive Variable speed drive ATV61 – 630kW 900HP – 380…480V – IP20

,

ATV61HD90M3X Schneider ATV61 DRIVES 90KW 3AC 200…240V

Mainrange of product

Altivar 61

product or component type

Variable speed drive

product specific application

Pumping and ventilation machine

component name

ATV61

motor power kW

90 kW 3 phasesat 200…240 V

motor power hp

125 hp 3 phasesat 200…240 V

[Us] rated supply voltage

200…240 V (- 15…10 %)

Phase

3 phases

line current

288 Afor 240 V 3 phases 90 kW / 125 hp 336 Afor 200 V 3 phases 90 kW / 125 hp

EMC filter

Without EMC filter

assembly style

With heat sink

apparent power

119.7 kVAfor 240 V 3 phases 90 kW / 125 hp

prospective line Isc

35 kA 3 phases

maximum transient current

431 Afor 60 s 3 phases

nominal switching frequency

2.5 kHz

switching frequency

2.5…8 kHz adjustable 2.5…8 kHz with derating factor

asynchronous motor control profile

Voltage/frequency ratio, 2 points Voltage/frequency ratio – Energy Saving, quadratic U/f Flux vector control without sensor, standard Voltage/frequency ratio, 5 points

synchronous motor control profile

Vector control without sensor, standard

communication port protocol

CANopen Modbus
,

ATV61HC11Y Schneider variable speed drive ATV61 – 110kW 690V 125HP

ATV61HC11Y Schneider variable speed drive ATV61 – 110kW

  • Variable Speed Drives and Soft Starters
  • Low Voltage AC General Purpose Drives
  • Altivar 61
  • variable speed drive ATV61 – 110kW / 690V – 125HP / 575V – IP20
  • range of product
    Altivar 61
    product or component type
    Variable speed drive
    product specific application
    Pumping and ventilation machine
    component name
    ATV61
    motor power kW
    110 kW 3 phases at 690 V 90 kW 3 phases at 500 V
    motor power hp
    125 hp 3 phases at 575 V
    [Us] rated supply voltage
    500…690 V (- 15…10 %)
    network number of phases
    3 phases
    line current
    113 A for 600 V 3 phases 90 kW / 125 hp 117 A for 690 V 3 phases 90 kW / 125 hp 128 A for 500 V 3 phases 90 kW / 125 hp
    EMC filter
    Level 3 EMC filter
    assembly style
    With heat sink