SCHNEIDER Altivar 71 ATV71HC11Y Variable speed drive

SCHNEIDER Altivar 71 ATV71HC11Y Variable speed drive

Model Number:ATV71HC11Y

Product Type:Drives

Type:

Category:

Plance of Origin:

Warranty:

Description:variable speed drive ATV71 – 110kW – 690V  

Main
Range of product Altivar 71
Product or component type Variable speed drive
Product specific application Complex, high-power machines
Component name ATV71
Motor power kW 110 kW, 3 phases at 690 V
90 kW, 3 phases at 500 V
Motor power hp 125 hp, 3 phases at 575 V
Maximum motor cable length 15 m shielded cable
30 m unshielded cable
power supply voltage 500…690 V – 15…10 %
Network number of phases 3 phases
Line current 113 A for 600 V 3 phases / 125 hp
117 A for 690 V 3 phases 110 kW
128 A for 500 V 3 phases 90 kW
EMC filter Integrated
Assembly style With heat sink
variant Reinforced version
Prospective line Isc 28 kA for 3 phases
Nominal output current 125 A at 2.5 kHz 575 V 3 phases / 125 hp
125 A at 2.5 kHz 690 V 3 phases 110 kW
136 A at 2.5 kHz 500 V 3 phases 90 kW
Maximum transient current 204 A for 60 s 3 phases 90 kW
224.4 A for 2 s 3 phases / 125 hp
224.4 A for 2 s 3 phases 110 kW
Output frequency 0.1…500 Hz
Nominal switching frequency 2.5 kHz
Switching frequency 2.5…4.9 kHz adjustable
2.5…4.9 kHz with derating factor
Asynchronous motor control profile Flux vector control (FVC) with sensor (current vector)
Voltage/frequency ratio (2 or 5 points)
ENA (Energy adaptation) system for unbalanced loads
Sensorless flux vector control (SFVC) (voltage or current vector)
Type of polarization No impedance for Modbus
Complementary
Product destination Synchronous motors
Asynchronous motors
power supply voltage limits 425…759 V
power supply frequency 50…60 Hz – 5…5 %
power supply frequency limits 47.5…63 Hz
Speed range 1…100 for asynchronous motor in open-loop mode, without speed feedback
1…1000 for asynchronous motor in closed-loop mode with encoder feedback
1…50 for synchronous motor in open-loop mode, without speed feedback
Speed accuracy +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn
+/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
+/- 5 % in closed-loop mode with encoder feedback
Transient overtorque 170 % of nominal motor torque +/- 10 % for 60 s every 10 minutes
220 % of nominal motor torque +/- 10 % for 2 s
Braking torque <= 150 % with braking or hoist resistor
30 % without braking resistor
Synchronous motor control profile Vector control without speed feedback
Regulation loop Adjustable PI regulator
Motor slip compensation Not available in voltage/frequency ratio (2 or 5 points)
Automatic whatever the load
Suppressable
Adjustable
diagnostic 1 LED (red) for drive voltage
Output voltage <= power supply voltage