SIEMENS SIMATIC MP 277 8″ TOUCH 6AV6643-0CB01-1AX1

SIEMENS SIMATIC MP 277 8″ TOUCH 6AV6643-0CB01-1AX1

Model Number:

Product Type:PLC Module

Type:

Category:SIEMENS/SIMATIC PANEL

Plance of Origin:Made in Germany

Warranty:All parts new or reconditioned are covered by AoteWell 12 month warranty

Description:AS OF 2015-01-01 THE PRODUCT IS BLOCKED FOR DELIVERY AND IS NO LONGER AVAILABLE AS A NEW PART. INFORMATION ABOUT SUCCESSOR SEE SIMATIC UPDATE ID: 62977695 FOR FURTHER QUESTIONS PLEASE APPROACH YOUR SIEMENS CONTACT PERSON. SIMATIC MP 277 8″ TOUCH MULTI PANEL W. RETENTIVE MEMORY 7.5″ TFT DISPLAY 6 MB CONFIGURING MEMORY, CONFIGURABLE WITH WINCC FLEXIBLE 2005 STANDARD SP1  

General information
Customer-specific configuration Yes
Display
Design of display TFT
Screen diagonal 7.5 in
Color display Yes
Number of colors 65 536
Resolution (pixels)
● Horizontal image resolution 640 Pixel
● Vertical image resolution 480 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 50 000 h
Control elements
Control elements Touch screen
Keyboard fonts
● System keys No
● alphanumeric keyboard Yes
● hexadecimal keyboard Yes
Touch operation
● Design as touch screen Yes; analog, resistive
Installation type/mounting
Mounting position vertical
maximum permissible angle of inclination without external ventilation 35°
Supply voltage
Type of supply voltage DC
Processor
Processor type ARM
Memory
Type of memory Flash / RAM
Memory available for user data 6 Mbyte
Capacity of main memory, max. 128 Mbyte
Time of day
Clock
● Type Hardware clock, battery backup, synchronizable
● retentive Yes
● synchronizable Yes
Interfaces
Interfaces/bus type 1 x RS422, 1 x RS485, 1 x Ethernet (RJ45)
Number of RS 485 interfaces 1
Number of USB interfaces 2; Up to 1 GB respectively
Multimedia card/SD card slot 1x Multimedia Card slot, up to 128 MB
Industrial Ethernet
● Industrial Ethernet interface 1 x Ethernet (RJ45)
Protocols
Supports protocol for PROFINET IO Yes
PROFIsafe No
PROFIBUS Yes
Protocols (Ethernet)
● TCP/IP Yes
Further protocols
● other bus systems Yes
Degree and class of protection
IP (at the front) IP65
NEMA (front) NEMA 4x (when installed)
IP (rear) IP20
Standards, approvals, certificates
Certifications CE, FM Class I Div. 2, UL, cULus, EX Zone 22, NEMA 4x (Enclosure Type 4X, Type 12)
cULus Yes
Suitable for safety functions No
Use in hazardous areas
● ATEX Zone 22 Yes
● FM Class I Division 2 Yes
Ambient conditions
Ambient temperature during operation
● min. 0 °C
● max. 50 °C
Ambient temperature during storage/transportation
● min. -20 °C
● max. 60 °C
Relative humidity
● Operation, max. 90 %
Operating systems
pre-installed operating system Windows CE
Configuration
Message indicator Yes
Alarm system (incl. buffer and acknowledgment) Yes
Process value display (output) Yes
Process value default (input) possible Yes
Recipe management Yes
Configuration software
● Configuration tool WinCC flexible Standard Version 2005 SP1 or higher (to be ordered separately)
● STEP 7 Basic (TIA Portal) No
● STEP 7 Professional (TIA Portal) No
● WinCC flexible Compact No
● WinCC flexible Standard Yes
● WinCC flexible Advanced Yes
● WinCC Basic (TIA Portal) No
● WinCC Comfort (TIA Portal) Yes
● WinCC Advanced (TIA Portal) Yes
● WinCC Professional (TIA Portal) Yes
Languages
Online languages
● Number of online/runtime languages 16
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Task planner Yes
Help system Yes
● Number of characters per info text 70
Message system
● Number of alarm classes 32
● Number of messages 4 000
● Bit messages Yes
— Number of bit messages 4 000
● Analog messages Yes
— Number of analog messages 200
● System messages HMI Yes
● System messages PLC Yes
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) Yes
● Lines 1
● Number of characters per message 80
● Number of process values per message 8
● Acknowledgment groups Yes
● Message indicator Yes
● First/last value Yes
Recipe management
● Number of recipes 300
● Data records per recipe 500
● Entries per data record 1 000
● Recipe memory 64 KB integrated Flash, expandable
Variables
● Number of variables per device 2 048
● Number of variables per screen 200
● Number of variables 1 000
● Type Date & Time 2 048
● Limit values Yes
● Multiplexing Yes
● Structures Yes
Images
● Number of configurable images 500
● Permanent window/default Yes
● Start screen configurable Yes
● Image selection by PLC Yes
● Image number in the PLC Yes
Image objects
● Text objects 10,000 text elements
● Number of I/O fields per image 200
● Number of date/time fields 200
● Return Yes
● Graphics object Bit maps, icons, vector graphics
— Icons 1 000
Complex image objects
● Status/control With SIMATIC S7
● dynamic objects Diagrams, bar graphs, sliders, analog display, invisible buttons
— Number of objects per project 1 000
— Number of curve diagrams per image 10
● Methods Trend / profile
● Bar graphs
— Number of bars per chart 10
● Sliders
— Number of slides per image 10
● Pointer instruments
— Number of analog indicators per image 10
● Limit value lines Yes
● Number of alphanumerical fields 300
— alphanumeric fields per image 200
● Number of numerical fields 2 048
— numerical fields per image 200
● Number of password fields 2 048
● Number of visible switches per project 200
— visible switches per image 200
— hidden switches per image 200
● Number of status switches per project 200
— Number of status switches per image 200
● Number of selector switches per project 200
— Selector switches per image 200
● Number of decade switches per project 200
— Decade switches per image 200
● Number of signal lamps per project 200
— Signal lamps per image 200
Attributes for dynamic objects
● Color change Yes
● X/Y movement Yes
● Hide Yes
Lists
● Number of text lists per project 500
● Number of text lists per image 200
● Number of entries per text list 256
● Number of graphics lists per project 400
● Number of graphic lists per image 200
● Number of entries per graphics list 256
Archiving
● Number of archives per device 20
● Number of measuring points per project 20
● Number of entries per archive 10 000
● Message archive Yes
● Process value archive Yes
● Archiving methods
— Sequential archive Yes
— Short-term archive Yes
● Memory location SD and MultiMediaCard
— Ethernet Yes
● Data storage format
— CSV Yes
● Online evaluation
— using trend curves Yes
Filters
● cyclic Yes
● Tolerance Yes
● Change Yes
Security
● Number of user groups 50
● Number of user rights 32
● Password export/import Yes
Logging through printer
● Recording/Printing Alarms, report (shift report), color print, hardcopy
Transfer (upload/download)
● Transfer of configuration MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition
Process coupling
● Connection to controller S5, S7-200, S7-300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus) see chapter “System interfaces”
● S7-1200 Yes
● S7-1500 Yes
● S7-200 Yes
— PPI (point-to-point) Yes
— PPI network Yes
— MPI Yes
— PROFIBUS DP Yes
— Ethernet Yes
● S7-300/400 Yes
— MPI Yes
— PROFIBUS DP Yes
— PROFINET Yes
● S5 Yes
— PROFIBUS DP Yes
● TI 505 Yes
● Allen Bradley (DF1) Yes
● Allen Bradley (DF485) Yes
● Mitsubishi (FX) Yes
● Mitsubishi (MP4) Yes
● Telemecanique (Uni-Telway) Yes
● OMRON (LINK/Multilink) Yes
● Modicon (Modbus) Yes
● GE-Fanuc (SNP) Yes
Functions
● TAB sequence Yes
● Calculating functions Yes
● Animate Yes
Service tools/configuration aids
● Clean screen Yes
● Touch calibration Yes
● Backup/Restore manually Yes
● Simulation Yes
● Device switchover Yes
● Delta transfer Yes
Expandability/openness
● Open Platform Program Yes
Peripherals/Options
Peripherals Printer, barcode reader
● SIMATIC HMI MM memory card: Multi Media Card Yes
● SIMATIC HMI SD memory card: Secure Digital memory card Yes
● USB memory Yes
Additional software components loadable Yes
Dimensions
Width of the housing front 250 mm
Height of housing front 190 mm
Mounting cutout, width 226 mm
Mounting cutout, height 166 mm
Overall depth 61 mm
Weights
Weight (without packaging) 1.61 kg